Auditing Medical Vision-Language Models for Chest X-Ray Tuberculosis Screening
Beyond Benchmark Scores: Auditing Medical Vision-Language Models for Chest X-Ray Tuberculosis Screening
This paper provides crucial evidence that benchmark scores for medical AI models can be misleading, as performance varies significantly based on the specific evaluation setup. This matters for anyone using or developing such models, as it highlights the importance of understanding the full context of a model's performance claims.
This study tests whether claims about model ranking, score reliability and screening performance survive changes in cohort, prompt, negative spectrum, specified prevalence and operating threshold.
It audits three medical vision-language models (BioMedCLIP, CheXficient, and MedSigLIP) and a general-domain OpenCLIP comparator on 12,200 chest radiograph records from four datasets (Montgomery, Shenzhen, TBX11K, and VinDr-CXR).
Prompt-family changes alter AUROC in 21 of 48 multiplicity-controlled comparisons.Replacing healthy controls with sick non-tuberculosis controls reduces AUROC by 0.
075--0.306 across all four models.
On VinDr-CXR, the three medical models distinguish tuberculosis from no-finding controls substantially better than from pneumonia or lung tumor;
their AUROC point estimates for both named diseases fall below 0.5.
CheXficient has documented VinDr-CXR pretraining exposure, which limits the interpretation of its results.Thresholds chosen for 95% sensitivity on TBX11K training retain that constraint by point estimate in only four of sixteen target evaluations.
A five-seed supervised source model reaches 0.999 AUROC on TBX11K validation but 0.
629 on each of two external cohorts.Conservative exclusion of perceptual-overlap candidates narrows this gap without closing it.
Beyond Benchmark Scores: Auditing Medical Vision-Language Models for Chest X-Ray Tuberculosis Screening
A medical model's benchmark score does not establish that the same conclusion holds under a different evaluation. This study tests whether claims about model ranking, score reliability and screening performance survive changes in cohort, prompt, negative spectrum, specified prevalence and operating threshold. We audit three medical vision-language models (BioMedCLIP, CheXficient, and MedSigLIP) and a general-domain OpenCLIP comparator on 12,200 chest radiograph records from four datasets (Montgomery, Shenzhen, TBX11K, and VinDr-CXR). Five fixed prompt families yield 244,000 model--image--prompt scores. No model leads every cohort and reliability criterion. Prompt-family changes alter AUROC in 21 of 48 multiplicity-controlled comparisons. Replacing healthy controls with sick non-tuberculosis controls reduces AUROC by 0.075--0.306 across all four models. On VinDr-CXR, the three medical models distinguish tuberculosis from no-finding controls substantially better than from pneumonia or lung tumor; their AUROC point estimates for both named diseases fall below 0.5. CheXficient has documented VinDr-CXR pretraining exposure, which limits the interpretation of its results. Thresholds chosen for 95\% sensitivity on TBX11K training retain that constraint by point estimate in only four of sixteen target evaluations. A five-seed supervised source model reaches 0.999 AUROC on TBX11K validation but 0.629 on each of two external cohorts. Conservative exclusion of perceptual-overlap candidates narrows this gap without closing it. These retrospective, single-task results show that discrimination, score reliability and threshold retention support different portability claims. Evidence for chest X-ray tuberculosis screening should identify the complete evaluation specification rather than attribute clinical portability to a checkpoint alone.
This report is categorized under AITOP's "Papers" desk, focusing on US frontier AI labs and Silicon Valley technology leaders. Within our cross-regional analytical framework, it directly maps to AI developer toolchains, coding agents, and engineering workflows and US-China foundation model benchmarks and commercialization comparison. Key entities and technical topics under continuous tracking include MedSigLIP, CheXficient, BioMedCLIP.
Source attribution: curated from arXiv cs.LG (@Mushir Akhtar, M. Tanveer, Mohd. Arshad).