Study finds reference choice impacts AI chest X-ray report evaluation
Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation
This matters to researchers and developers in the medical AI field because it highlights a critical flaw in how AI models for generating medical reports are currently evaluated.
A new paper quantifies how variations in radiologist reporting practices affect the evaluation of AI-based radiology report generation models.
The study reveals that current metrics can be sensitive to these variations, potentially altering model rankings.
It introduces a method called ReRef to rewrite reference reports while preserving clinical interpretation and releases a new dataset for future research.
Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation
Radiologists follow heterogeneous reporting practices. Two radiologists examining the same image and identifying the same clinical findings might nevertheless compose superficially distinct reports, varying in terminology, shorthand, formatting, and level of detail. These variations in reporting norms represent an under-appreciated obstacle in efforts to evaluate AI-based radiology report generation (RRG) models, where machine-generated reports are typically assessed based on their concordance with human-generated references. In this paper, we quantify the sensitivity of established evaluation metrics to variations in reporting practices, revealing impacts large enough to alter the rankings of models. We introduce a radiologist-informed taxonomy of variations in radiology reporting practice and a method (ReRef) that rewrites reference reports along the axes of our taxonomy while preserving clinical interpretation. For instance, when comparing the performance of nine RRG models on MIMIC-CXR using RadCliQ-v1, condensing the discussion of normal findings in the reference reports causes Libra to drop from first to second place while CheXOne rises from third to first. Our results suggest that many current metrics fail to decouple clinical interpretation from conformity to reporting practices and that choosing the ``right'' references that accurately reflect the desired reporting practices can be important in practice. To support future research, we release MIMIC-CXR-Ext-ReRef, a radiologist-validated dataset of 120 (original, alternative) reference report pairs derived from MIMIC-CXR.
This report is categorized under AITOP's "Papers" desk, focusing on US frontier AI labs and Silicon Valley technology leaders. Within our cross-regional analytical framework, it directly maps to AI developer toolchains, coding agents, and engineering workflows and AI regulation, compliance frameworks, and sovereign compute policy. Key entities and technical topics under continuous tracking include AI safety, RAG, fine-tuning, prompt engineering.
Source attribution: curated from arXiv cs.AI (@Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency, Pradeep Ravikumar, Zachary C. Lipton, Michael Oberst).