MedAgentBench 容错注入研究:LLM 评审识别临床危险动作的能力实测
Can LLM Judges Catch Unsafe Clinical Actions? A Fault-Injection Study
临床智能体上线前必须回答的问题:谁来检查它没犯错。这篇研究给出具体数字——只看最终答案的评审会误伤一半正确操作,但加上 EHR 记录和规则检查器能抓到 97% 错误。做医疗 AI 评测的开发者值得照着这套方法搭一遍。
一项基于 MedAgentBench 的容错注入研究检验了 LLM 评审识别临床智能体不安全动作的能力。研究构建了 416 条含错误轨迹的测试集,覆盖八类临床错误,并让六个开源权重 LLM 评审进行判别。
实验表明评审输入的信息形态决定可靠性:只看最终答案时,评审无法识别不改变答案的错误,还会把 56% 的正确轨迹误判为不安全;提供完整轨迹后判别分数达到 0.75,而给出真实 EHR 响应再提升 0.39。意外的是,加入智能体推理过程反而降低对错误临床数值的检测 0.18,这类错误最难发现。MedGemma 表现不如通用模型,且是唯一漏掉潜在用药过量风险的评审。
研究还发现 MedAgentBench 原始评分器接受了全部 38 条故意跳过实验室检查的轨迹,而将 LLM 评审与基于完整 EHR 记录的规则检查器结合后,可检测 97% 的注入错误。
Can LLM Judges Catch Unsafe Clinical Actions? A Fault-Injection Study
As clinical AI agents begin to interact with electronic health records (EHRs), large language models (LLMs) are increasingly used to evaluate their actions. But how reliably can these judges recognize clinically dangerous mistakes, especially when an agent appears to have completed its task successfully? We investigate this question using MedAgentBench by introducing controlled clinical errors into verified agent trajectories. The experiments include 416 faulty trajectories, eight error categories, and six open-weight LLM judges. By comparing each faulty trajectory with its correct counterpart, we measure whether judges genuinely recognize errors rather than simply flagging more actions as unsafe. The findings show that access to clinical evidence significantly improves judge reliability. When shown only the final answer, judges cannot distinguish errors that leave it unchanged, while flagging 56% of correct trajectories. With full trajectory information, the ability to distinguish unsafe actions from correct ones reaches a score of 0.75, and providing actual EHR responses improves discrimination by 0.39. Surprisingly, including the agent's reasoning does not improve overall performance and reduces detection of incorrectly reported clinical values by 0.18, which remain the hardest errors to detect. MedGemma performed worse than the general-purpose model and was the only judge to miss potentially dangerous medication overdoses. We also find that the benchmark's original grader accepts all 38 trajectories with an intentionally skipped laboratory check, while combining LLM judges with a rule-based checker informed by the full EHR record detects 97% of injected faults.
This report is categorized under AITOP's "Papers" desk, focusing on US frontier AI labs and Silicon Valley technology leaders. Within our cross-regional analytical framework, it directly maps to AI developer toolchains, coding agents, and engineering workflows. Key entities and technical topics under continuous tracking include MedAgentBench, MedGemma, AI safety, EHR.
Source attribution: curated from arXiv cs.AI (@Neda Ghafouri).