SeqSmoother:从腕部加速度计估算睡眠心率,MAE 低至 1.60 bpm
Deep Learning for Sleep Heart Rate Estimation from Accelerometers: Toward Population-Scale Cardiac Insight Without Optical Sensors
不用光学传感器,光靠手表加速度数据就能估睡眠心率,SeqSmoother 把 MAE 做到 1.60 bpm,还跟 Nightbeat 掰了手腕,精度和覆盖率的取舍讲得很清楚。
arXiv 论文提出 SeqSmoother,一个基于 transformer 的睡眠心率估算模型,仅用腕部加速度计信号推断心率。
模型结合频谱特征、Nightbeat 频率锚点和物理启定的次谐波特征,用于识别谐波锁定。在 13 个参与者互斥的留出折上,SeqSmoother 的参与者宏平均 MAE 为 1.
60 bpm。与官方 Nightbeat 在 60 秒窗口、15 秒步长协议下对比:Nightbeat 在保留区间上绝对误差更低(0.
615 vs 1.091 bpm),但仅对 72.
85% 的有效网格给出结果,SeqSmoother 覆盖范围更大。次谐波比率识别谐波锁定的 AUROC 达到 0.
972。
Deep Learning for Sleep Heart Rate Estimation from Accelerometers: Toward Population-Scale Cardiac Insight Without Optical Sensors
Large longitudinal cohorts often contain wrist accelerometry without optical heart-rate sensing, motivating recovery of cardiac information from motion signals already collected during sleep. We present SeqSmoother, a transformer-based temporal corrector for sleep heart rate (HR) estimation from wrist accelerometry. SeqSmoother combines spectral descriptors with an intermediate Nightbeat-derived frequency anchor and a physics-motivated sub-harmonic feature designed to identify harmonic frequency lock-on. All inference-time features are derived from wrist accelerometry, while ECG is used only to construct reference HR labels and training-label quality weights. We evaluate SeqSmoother using 13 participant-disjoint held-out folds and compare it with the official Nightbeat implementation under a matched 60-s window and 15-s step protocol. Across all out-of-fold predictions, SeqSmoother achieved a participant-macro MAE of 1.60 bpm. On Nightbeat-retained matched intervals, Nightbeat achieved lower absolute error than SeqSmoother (0.615 versus 1.091 bpm), while SeqSmoother provided estimates over a larger portion of the eligible recording; Nightbeat produced final estimates for 72.85% of the SeqSmoother-eligible out-of-fold grid. Separately, the proposed sub-harmonic ratio achieved an AUROC of 0.972 for identifying reference-defined harmonic lock-on candidates. These findings reveal an accuracy-availability trade-off between learned temporal modeling and quality-gated signal processing while providing empirical support for a physics-informed approach to identifying frequency-tracking failures in accelerometer-based sleep HR estimation.
This report is categorized under AITOP's "Papers" desk. Within our cross-regional analytical framework, it directly maps to AI developer toolchains, coding agents, and engineering workflows. Key entities and technical topics under continuous tracking include SeqSmoother, Nightbeat, sleep tracking, transformer.
Source attribution: curated from arXiv cs.AI (@Tanbin Islam Rohan, Pranjol Sen Gupta, Tanusree Debi, Nazmus Sakib).